ROOF SHIELD Ultra is a heavy duty terrace waterproof coating system, composed of specially
developed highly elastic & resilient acrylic polymers, properly selected & graded fillers, light fast & weather
durable pigments with micro-fibres, additives & best quality fungicidal in agues medium. It is used as a liquid
applied waterproofing membrane for all types of building terraces.
ROOF SHIELD Ultra is a three-layer system ensuring proper build-up of the thickness, making it a reliable waterproofing system.
The coating performance can be enhanced for large roofs, by providing a fibre mesh that is embedded or sandwiched between the coats.
Packaging
Available in 4 kg and 20 kg Bucket
Features / Benefits
- REDUCE TEMPERATURE UP TO 10 OC.
- High Elongation.
- UV Protected.
- Stops Terrace water Leakage.
- Reduces Electricity Consumption.
- Long Lasting.
Features / Benefits
- Dilute 2 parts of JOINTSEAL ROOFSHEILD Ultra with 1 one
part of water. This dilution will cover 7 to 8 sq. mt. Allow it to dry for 6 to 8 hrs.
- Apply the first coat of JOINTSEAL ROOFSHEILD Ultra
without any dilution and allow it to dry before taking up the second and third coats.
- In larger roofs, an open woven glass fiber mesh of 2.5
mm must be sandwiched between the first and second coat. While the 1st coat is still wet, place the fiber mesh on
it. After the coat dries, start applying the 2nd coat of JOINTSEAL ROOFSHEILD Ultra.This improves the performance of the coating
dramatically, to take care of all movements in cracks and cold joints in the substrate caused by variations of high and
low temperatures. This reinforcement with fiber mesh shall be extended up to the drip mould over the angle fillets.
- Drying time between coats will be 6 to 8 hrs.
- Allow the system to air cure for 7 days minimum. A total
thickness of 1 to 1.2 mm must be achieved when JOINTSEALROOFSHEILD Ultra is dry.
- 7 days after application of JOINTSEAL ROOFSHEILD Ultra,
it should be checked for its adhesion to the substrate.For this, mark a square of 5 cm x 5 cm, for every 200 sq. m
of the area.
- Cut the square with a knife diagonally across the square.
Rip the coating and check the coating’s thickness with venire calipers,
to seeif the dry film has an average thickness of 1 mm. This should be done in every 200 m2. over the entire roof.
Once these tests are done, re-apply JOINTSEAL ROOFSHEILD Ultra over these portions, in accordance with the regular procedure.